![TYPE J - FIBERGLASS INSULATED CABLE WITH BRAIDED ARMOUR](https://www.siccet.com/images/prodotti/20241015104736.png)
DESCRIPTION
Fiberglass insulation - fiberglass inner braid - tin plated copper braided armour (DIN colour code)
APPLICATION
High temperature and/or fire resistance
CONSTRUCTION
- Reference standard: DIN 43714
- Conductor: solid or stranded
- Insulation: braided fiberglass type “E” or “R/S” (lapped fiberglass version also available)
- Core laying – up: twisted conductors with fiberglass filler
- Inner layer: braided fiberglass type “E” or “R/S”
- Impregnation: liquid silicone resin or varnish
- Outer armour: tin plated copper wire braid
- Working temperature: + 400°C type “E” , + 650°C type “R/S” (HT)
- Insulation resistance: > 20 Mohm x km (measured at 1000 Volt dc @ 20 °C)
ALTERNATIVE VERSION
- IEC 60584 part 1,2,3
- ASTM E230 (ANSI MC96.1-1982)
- BS 1843
- NFC 42324
- JIS C 1610-1981
Applications
Customized solutions to meet every specific need
Show allMaterials
High-quality materials for superior performance
Our cables are characterized by insulating materials and sheaths that provide unique properties. These high-quality materials offer tailored performance for each application requirement.
Show all